Odorant Control

As a safety measure for consumers, gases in the public gas supply must contain sufficient warning odor. The correct odorisation affects the gas such that it takes on a typical, distinctive odor which reaches the level of a warning odor before the gas concentration becomes hazardous.

In accordance with DVGW (German Technical and Scientific Association for Gas and Water) G 280 (A), a minimum concentration of the odorant is required in the gas pipe network. This concentration must be checked at least twice a year at representative point as far as possible from the odorisation station. 

SEWERIN offers comprehensive service for the regular cycle of measurements - by request, in a maintenance contract.

  • Method in accordance with DVGW (German Technical and Scientific Association for Gas and Water) G 280 (A)
  • Chromatography for the analysis in accordance with ISO 6326 and DIN 51 855-7-GC
  • All odorants, e.g. S-Free, THT and TBM
  • All gas families
  • PC supported measurement and documentation


Contact:

Stefan Hoffmann
Phone:+49 5241 934-450
Fax:+49 5241 934-455
E-mail:dienstleistungen[at]sewerin.com